MODEL
(GS Series)
|
HV/LV Model
|
HV Model(4-10KW) LV Model(4-6KW)
|
Line Mode Specifications:
|
Input Voltage
|
Input Voltage Waveform
|
Sinusoidal (utility or generator)
|
Nominal Input Voltage
|
LV 120Vac
|
HV 230Vac
|
Low Line Disconnect
|
Normal:85Vac±4% Wide:80Vac±4%
|
Normal:184Vac±4% Wide:135Vac±4%
|
Low Line Re-connect
|
Normal:95Vac±4% Wide:85Vac±4%
|
Normal:194Vac±4% Wide:145Vac±4%
|
High Line Disconnect
|
Normal:136Vac±4% Wide:140Vac±4%
|
Normal:263Vac±4% Wide:263Vac±4%
|
High Line Re-connect
|
Normal:131Vac±4% Wide:135Vac±4%
|
Normal:253Vac±4% Wide:253Vac±4%
|
Max AC Input Voltage
|
150Vrms
|
270Vrms
|
Input Frequency
|
Nominal Input Frequency
|
50Hz/ 60Hz (Auto detection)
|
Low Line Frequency Re-connect
|
51+0.3Hz for 60Hz;
41+0.3Hz for 50Hz;
|
Low Line Frequency Disconnect
|
50+0.3Hz for 60Hz;
40+0.3Hz for 50Hz;
|
High Line Frequency Re-connect
|
64+0.3Hz for 60Hz;
54+0.3Hz for 50Hz;
|
High Line Frequency Disconnect
|
65+0.3Hz for 60Hz;
55+0.3Hz for 50Hz;
|
main functions
|
Output Voltage Waveform
|
As same as Input Waveform
|
Over-Load Protection (SMPS load)
|
Air switch
|
Output Short Circuit Protection
|
Air switch
|
Max Bypass Overload Current
|
40A/50A/80A
|
Battery Invert Mode Specifications:
|
AC output
|
Output Voltage Waveform
|
Sine wave
|
Rated Output Power (KW)
|
LV:4KW/5KW/6KW
|
HV: 4KW/5KW/
6KW/7KW/8KW/10KW
|
Power Factor
|
0.9~1.0
|
Nominal Output Voltage (V)
|
LV:120Vac ±10%rms
|
HV:230Vac ±10%rms
|
Nominal Output Frequency (Hz)
|
60Hz ± 0.3Hz
50Hz ± 0.3Hz
|
DC Voltage
|
Nominal DC Input Voltage
|
24VDC/48VDC
|
DC Voltage range
|
20-31.0Vdc for 24VDC
40-62.0Vdc for 48VDC
|
Low Battery Alarm
|
21.0Vdc ± 0.6Vdc for 24V battery
42.0Vdc ± 1.2Vdc for 48V battery
|
Low DC input Shut-down
|
20.0vdc± 0.6Vdc for 24V battery
40.0Vdc ± 1.2Vdc for 48V battery
|
High DC input Alarm & Fault
|
32Vdc ± 0.6Vdc for 24V battery
64Vdc ± 1.2Vdc for 48V battery
|
High DC input Recovery
|
31.0Vdc ± 0.6Vdc for 24V battery
62.0Vdc ± 1.2Vdc for 48V battery
|
AC Charger
|
Nominal Charge Current
|
35A/50A/70A (5 stages adjustable charging current)
|
Charge Current Regulation
|
± 5Adc
|
Over Charge Protection
|
Bat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
|
Algorithm
|
Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) →Float (constant voltage stage)
|
Solar charger
|
Rated Charge Current
|
40A
|
60A
|
Rated charge battery Voltage type
|
24V/48V
|
24V
|
Max.PV open circuit array voltage
|
24V for 55Vdc
48V for 110Vdc
|
Charger mode
|
MPPT
|
PV Low Voltage Re-connect
|
PV≥Bat.V=3V
|
PV Low Voltage Disconnect
|
PV≦Bat.V
|
Efficiency
|
≥97%
|
Efficiency
|
Efficiency (Battery Mode)
|
≥85%
|
Efficiency (Line Mode)
|
>98%
|
Transfer Time
|
Ac to Dc
|
20ms (Max)
|
Dc to Ac
|
15ms (Max)
|
System parameter
|
Over-Load Protection
|
110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s.
|
Output Short Circuit Protection
|
Current limit (Fault after 10s)
|
Surge rating (10s)
|
1:3 (VA)
|
Power saver
|
Load ≦25W (Enabled on “P/S auto” setting of Remote control)
|
Protections
|
Low battery, over charging, over load , over temp.
|
Indicators
|
LED+LCD Display
|
General Specifications
|
Operating Temperature Range
|
0°Cto 40°C
|
Storage temperature
|
-15ºC ~60ºC
|
Operation humidity
|
5% to 95%(non-condensing)
|
Audible Noise
|
60dB max
|
Cooling
|
Forced air, variable speed fan
|
Dimension(L*W*H)
|
4KW
|
5KW
|
6KW
|
7KW
|
8KW
|
10KW
|
530*400*190mm
|
590*420*195mm
|
Net weight(Kg)
|
30.0
|
35.5
|
38.5
|
41.5
|
48.0
|
55.0
|